Fire protection collars Rorcol V60 for the closing of plastic pipes made of PE, PP, PVC, multi-layer pipes (with or without isolation: polyethylene, elastomer foam, mineral wool, polyester nonwoven or composite phonic insulation). A 60 mm deep stainless steel housing with internal, three-dimensionally expanding intumescent (from about 150 °C) and an integrated mounting clip extension for spanning large annular gaps.

Suitable for the construction and installation, oblique services, omega-use and many other special applications. Shaft walls from 40 mm thickness...

↓ Read more

Fire protection collars Rorcol V60 for the closing of plastic pipes made of PE, PP, PVC, multi-layer pipes (with or without isolation: polyethylene, elastomer foam, mineral wool, polyester nonwoven or composite phonic insulation). A 60 mm deep stainless steel housing with internal, three-dimensionally expanding intumescent (from about 150 °C) and an integrated mounting clip extension for spanning large annular gaps.

Suitable for the construction and installation, oblique services, omega-use and many other special applications. Shaft walls from 40 mm thickness, solid and stud (flexible) walls from 100 mm, laminated timber ceiling and solid ceilings from 150 mm and EPS lightweight concrete from 200 mm (for installation in EPS lightweight concrete blocks using the Rorcol installation aid is required). Tested and classified in various mineral wool batts systems for walls and ceilings. Suitable for plastic pipes.

All types of RORCOL fire protection collars can be used with zero distance between themselves and with 50 mm distance from Air Fire Tech fire barriers and fire dampers. Tested according to EN 1366-3, EI90 / EI120 classified according to EN 13501-2 and approved acc. ETA 13/0758. CE marking according to ETAG 026 Part 2.

Extra information
  • Housing made of stainless steel
  • Extensive range of applications and special applications
  • U/U tested
  • Plastic pipes up to Ø 250 mm
  • Omega-application possible up to Ø 110 mm
  • Integrated mounting clip extension for spanning large annular gaps
  • 50 mm from the Air Fire Tech fire barriers and fire dampers
  • Zero distance between the fire protection sleeves
  • Installation approved in laminated timber constructions
  • Approved installation in shaft walls from 40 mm thickness
  • Tested for all common pipes and insulating materials as well as combinations
  • Approved for installation in walls and ceilings